The air catches you wherever you go, for your maximum comfort
Round-way Cassette

The outlet adopts stepper motor design to realize the four-direction independent control system.

2.5 ...18 kW
Heating сapacity:
2.2 ...16 kW
Cooling сapacity:
Key features:
Key features:
  • Exclusive 360° air flow system for a uniform air distribution
  • Independent control of the 4 vanes
  • 6 levels of positioning per individual vane
  • DC inverter fan motor
  • 5 fan speeds ONLY selectable with wired controller MWI-R201ABK and with wireless controller MIR-RS01
  • Standard condensate drain pump with 700mm lift
  • Side inlet for fresh air (pre-cut)
Quiet operation, create a peaceful space
  • High efficiency brushless DC fan motor, achieve step-less adjustment for speed, greatly reduce the noise of operation
  • Optimize the traditional air duct design, adopt sound insulation wall technology, effectively reduce the eddy current range, block the transmission path of noise, effectively reduce the noise about 3dB(A)
  • Fan optimization design, using the principle of fluid mechanics, referring to the design of aviation structure, so that the airflow speed distribution is uniform, reduce the airflow resistance, so as to reduce noise, to achieve quiet operation.

 

Note: * Other ac motor standards are optional

Standard drain pump

Standard drain pump, the lift is 700mm and built-in float switch, convenient to cooperate with the actual situation to condensate water discharge air conditioning.

Streamlined outlook design
Streamlined outlook design

Buy a traditional grille and a dynamic windmill for multi-choice and multi-enjoyment. Buy a dynamic windmill to enjoy a dynamic mood and relax in the wind.

Energy saving control
Energy saving control

The product adopts MOVE EYE module (optional), which can be controlled to realize the function of switch-on when people coming in and switch-off when people leaving.

Four way indepent air flow
Four way indepent air flow

Individual louvers control allows users to precisely manage the direction of airflow in four different directions.

Wide opening angle range
Wide opening angle range

With adjustable louvers and multiple fan speed settings, users can customize the direction and intensity of airflow.

Specifications Units MIBR-07X1EV1AD MIBR-09X1EV1AD MIBR-12X1EV1AD MIBR-16X1EV1AD MIBR-18X1EV1AD MIBR-24X1EV1AD
Capacity
Cooling kW 2,20 2,80 3,60 4,50 5,60 7,10
Heating kW 2,50 3,20 4,00 5,00 6.,30 8,00
Electrical Parameters
Power supply Ph/V/Hz 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60)
Ventilation
Air flow (H/M/L) m3/h 1000/810/620 1000/810/620 1000/810/620 1000/810/620 1000/810/620 1380/1190/1000
Sound pressure
(H/M/L)
dB(A) 30/27/25 30/27/25 30/27/25 32/29/27 33/30/29 35/34/31
Installation – Dimensions
Net dimensions
(WxDxH)
mm 840x840x180 840x840x183 840x840x204
Packaged unit dimensions
(WxDxH)
mm 983x983x268 983x983x290
Net/gross weight Kg 25,0/28,0 25,0/28,0 25,0/28,0 28/31 28/31 29/32
Ø Liquid pipe mm (inch) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 9,52 (3/8)
Ø Gas pipe mm (inch) 9,52 (3/8) 9,52 (3/8) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 15,88 (5/8)
Panel
Model   MB-950KB MB-950KB MB-950KB MB-950KB MB-950KB MB-950KB
Panel Net dimensions
(WxDxH)
mm 950x950x50 950x950x50 950x950x50 950x950x50 950x950x50 950x950x50
Panel Packaging dimensions
(WxDxH)
mm 1013x1025x123 1013x1025x123 1013x1025x123 1013x1025x123 1013x1025x123 1013x1025x123
Panel Net/gross weight Kg 6,5/9,0 6,5/9,0 6,5/9,0 6.5/9 6.5/9 6.5/9

 

 

Specifications Units MIBR-28X1EV1AD MIBR-30X1EV1AD MIBR-38X1EV1AD MIBR-48X1EV1AD MIBR-60X1EV1AD
Capacity
Cooling kW 8,00 9,00 11,20 14,00 16,00
Heating kW 9,00 10,00 12,50 16,00 18,00
Electrical Parameters
Power supply Ph/V/Hz 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60) 1/220-230/50/(60)
Ventilation
Air flow (H/M/L) m3/h 1380/1190/1000 2050/1860/1670 2050/1860/1670 2100/1910/1720 2100/1910/1720
Sound pressure
(H/M/L)
dB(A) 37/35/31 37/35/31 37/35/31 44/40/36 44/40/36
Installation – Dimensions
Net dimensions
(WxDxH)
mm 840x840x246 840x840x288
Packaged unit dimensions
(WxDxH)
mm 983x983x331 983x983x331 983x983x373
Net/gross weight Kg 27,0/30,0 31,0/36,0 31,0/36,0 33,0/38,0 33,0/38,0
Ø Liquid pipe mm (inch) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Ø Gas pipe mm (inch) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Panel
Model   MB-950KB MB-950KB MB-950KB MB-950KB MB-950KB
Panel Net dimensions
(WxDxH)
mm 950x950x50 950x950x50 950x950x50 950x950x50 950x950x50
Panel Packaging dimensions
(WxDxH)
mm 1013x1025x123 1013x1025x123 1013x1025x123 1013x1025x123 1013x1025x123
Panel Net/gross weight Kg 6,5/9,0 6,5/9,0 6.5/9 6.5/9 6.5/9
Dimensions
MIBR-07X1EV1AD MIBR-09X1EV1AD MIBR-12X1EV1AD MIBR-16X1EV1AD MIBR-18X1EV1AD MIBR-24X1EV1AD MIBR-28X1EV1AD MIBR-30X1EV1AD MIBR-38X1EV1AD MIBR-48X1EV1AD MIBR-60X1EV1AD
Dimensions
Want to buy

Feedback form

Invitation to cooperation