Low ESP slim duct | Unternehmen Mycond (Mykond) für Klimaanlagen
GTranslate
German

Low ESP slim duct

Slim ducts are designed to fit into tight spaces, making them suitable for installations in areas where conventional ductwork may not be feasible
Low ESP slim duct
Key features:
  • Ideal for bedrooms, hotel rooms and quiet environments
  • Extremely slim: height only 185 mm
  • Ready for fresh air (pre-cut side inlet)
  • Standard condensate drain pump
  • Convertible air intake: lower or rear by moving the panel as standard
  • Silent operation
  • Designed for free-mount installation without duct or with short ducts. Adjustable ESP 0/15/30 Pa by using with wired controllers: MWI-R101ABT, MWIR201ABK (DC-fan version only)
  • Ability to control via IR-remote controller using decorative panel with IR-receiver or separate IRreceiver MIR-B101DB
  • Optional UVC-lamp to sterilize the air that flows through the unit
  • Optional aesthetic decorative panel: inlet and outlet (with louvers)
  • Optional DC inverter fan motor
Adjusted esp super slim save installation space agile and convenient
Adjusted esp super slim save installation space agile and convenient

Fuselage thickness of only 180mm, easy to install in the height of narrow residential ceiling, fuselage depth of only 450mm, save the ceiling area, and fully cooperate with the interior decoration.

Quiet operation
  • High efficiency model * High efficiency brushless DC motor, speed stepless adjustment, can achieve seven air supply, greatly reduce operating noise
  • Through the reasonable design of indoor unit thermal components and internal air duct, four block wind speed, silent operation is realized. Note: The standard model of AC motor is also available
Return air mode selection according to local conditions — more user-friendly installation
Return air mode selection according to local conditions — more user-friendly installation

Provide bottom and rear two return air modes, indoor installation more flexible and convenient, users can choose the best installation scheme according to the characteristics of interior decoration. Note: If there is enough installation space, it is recommended to use the side feed back mode, which can effectively reduce the running sound.

High lift-up drain pump
High lift-up drain pump

Standard condensate water lifting pump, standard head 700mm, special models customized range up to 1200mm, and built-in float switch, convenient to cooperate with the actual situation of the site, condensate water discharge air conditioning.

3D three-dimensional air supply

Optional air inlet/outlet decorative panels
Optional air inlet/outlet decorative panels

Decorative panels allow you to harmoniously fit the inlet and outlet grilles into the interior.

3D airflow
3D airflow

The presence of separate controls for vertical and horizontal louvers allows you to create a comfortable 3D air flow in the required direction.

Super slim design
Super slim design

The height of low ESP slim duct unit is only 185mm, which is industry leading and provides the smallest ceiling drop.

Adjusted esp by wired controller
Adjusted esp by wired controller

ESP can be adjusted by using wired controllers MWIR201ABK or MWI-R101ABT. And installer don’ t need to climb the ladders to make the settings. There are 3 steps of ESP available (DCfan version only): 0/15/30 Pa.

Specifications Units MIDS-05X1EV1AA MIDS-07X1EV1AA MIDS-09X1EV1AA MIDS-12X1EV1AA MIDS-16X1EV1AA MIDS-18X1EV1AA MIDS-24X1EV1AA
Capacity  
Cooling kW 1,50 2,20 2,80 3,60 4,50 5,60 7,10
Heating kW 1,70 2,50 3,20 4,00 5,00 6,30 8,00
Electrical Parameters  
Power supply Ph/V/Hz 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60 1/220-230/50/60
Ventilation  
Air flow (H/M/L) m3/h 430/370/310 480/420/360 480/420/360 550/430/370 600/540/460 800/690/580 930/850/750
Sound pressure
(H/M/L)
dB(A) 26/22/19 27/23/20 27/23/20 30/27/24 32/29/26 33/30/27 36/33/30
Sound power
(H/M/L)
dB(A) 40/36/33 41/37/34 41/37/34 44/41/38 46/43/40 47/44/41 50/47/43
Installation – Dimensions  
Unit Dimensions
WxDxH
mm 850x420x185 850x420x185 850x420x185 850x420x185 850x420x185 1170x420x185 1170x420x185
Packaged unit
dimensions WxDxH
mm 1045x540x270 1045x540x270 1045x540x270 1045x540x270 1045x540x270 1365x540x270 1365x540x270
Net weight / Gross
weight
Kg 16,5/21,5 17,5/22,5 17,5/22,5 17,5/22,5 18,5/23,5 22,2/28,2 24,0/30,0
Ø Liquid side
refrigerant pipe
mm (inch) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 9,52 (3/8)
Ø Gas side
refrigerant pipe
mm (inch) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 15,88 (5/8)
Static pressure
(Standard / Max)
Pa 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30 0/15/30
Panel  
Model   M1B-890IA/D M1B-890IA/D M1B-890IA/D M1B-890IA/D M1B-890IA/D M1B-1210IA/D M1B-1210IA/D
Dimensions WxDxH (outlet
panel)
mm 890x190x100 890x190x100 890x190x100 890x190x100 890x190x100 1210x190x100 1210x190x100
Dimensions WxDxH (intake
panel with filter)
mm 890x290,5x32,4 890x290,5x32,4 890x290,5x32,4 890x290,5x32,4 890x290,5x32,4 1210x290,5x32,4 1210x290,5x32,4
Packaging
dimensions WxDxH
mm 938x335x220 938x335x220 938x335x220 938x335x220 938x335x220 1258x335x220 1258x335x220
Net weight / Gross
weight
Kg 4,0/5,0 4,0/5,0 4,0/5,0 4,0/5,0 4,0/5,0 5,0/6,0 5,0/6,0
Dimensions
MIDS-05X1EV2AD(H) MIDS-07X1EV2AD(H) MIDS-09X1EV2AD(H) MIDS-12X1EV2AD(H) MIDS-16X1EV2AD(H) MIDS-05X1EV1AD MIDS-07X1EV1AD MIDS-09X1EV1AD MIDS-12X1EV1AD MIDS-16X1EV1AD MIDS-05X1EV1AA MIDS-07X1EV1AA MIDS-09X1EV1AA MIDS-12X1EV1AA MIDS-16X1EV1AA
Dimensions
Dimensions
MIDG-18X1EV2AD(H) MIDG-24X1EV2AD(H) MIDG-18X1EV2AD MIDG-24X1EV2AD MIDS-18X1EV1AA MIDS-24X1EV1AA
Dimensions
Want to buy