Four-way cassette-type fan coil unit TopLine series

A cassette-type fan coil unit is a combination of advanced technology with cutting-edge, elegant, minimalistic design, ensuring the highest level of comfort in your space
Four-way cassette-type fan coil unit TopLine series

With their high efficiency, TopLine fan coil units can quickly cool or heat the room to provide a comfortable environment for the inhabitants. The fan coil units are rugged in design and are capable of long-term fault-free operation.

1,25 … 10,93 kW
Cooling capacity:
1,38 … 11,72 kW
Heating capacity:
Features and advantages:
Features and advantages:
  • Models 1-2-3 are 572х572 mm in size, which allows using them with an ARMSTRONG slab.
  • With a four-way air distribution system, the unit can uniformly heat or cool the room without creating any draughts or uncomfortable conditions.
  • The fan is designed to ensure quiet operation.
  • AC or DC motor to choose from.
  • The fan coil unit can be designed with either 2 or 4 pipes.
  • A built-in drainage pump with 650 mm condensate lift.
  • The unit can be controlled with either an infrared control or a wall-mounted control panel, with the louvres being adjusted manually in both cases.
  • The escutcheon is made of eco-friendly material.
  • The air filter is easily accessible and easy to clean.
  • The unit is designed with a fresh air intake opening.

2 pipe units.

 

Specifications Units TL 0.2T TL 1.2T TL 2.2T TL 3.2T
Speed   1 2 3 1 2 3 1 2 3 1 2 3
Air flow m3/h 310 420 610 310 420 520 320 500 710 430 610 880
Cooling total emission kW 1,25 1,60 1,92 1,82 2,31 2,64 2,23 3,30 4,26 2,91 3,82 4,93
Cooling sensible emission kW 0,99 1,29 1,58 1,33 1,72 2,00 1,55 2,35 3,11 2,05 2,75 3,65
Heating kW 1,38 1,80 2,24 1,85 2,42 2,80 2,12 3,28 4,37 2,85 3,85 5,15
Dp Cooling kPa 4,5 7,0 10,0 4,9 7,6 9,7 6,4 13,0 20,9 7,5 12,4 19,7
Dp Heating kPa 4,4 7,2 10,7 4,3 6,9 9,0 2,8 6,1 10,2 6,2 10,6 17,8
Sound power Lw dB(A) 33 40 49 33 40 45 33 45 53 41 49 59
Sound pressure Lp (*) dB(A) 24 31 40 24 31 36 24 36 44 32 40 50
Fan W 25 32 57 25 32 44 25 44 68 32 57 90
  А 0,11 0,15 0,27 0,11 0,15 0,20 0,11 0,20 0,32 0,15 0,27 0,45
Water content l 0,8 1,4 2,1 2,1
Dimensions mm 575×575×275

 

Specifications Units TL 4.2T TL 5.2T TL 6.2T
Speed   1 2 3 1 2 3 1 2 3
Air flow m3/h 630 820 1140 710 970 1500 710 1280 1820
Cooling total emission kW 4,18 4,86 6,08 5,27 6,72 9,39 5,27 8,36 10,93
Cooling sensible emission kW 3,00 3,53 4,51 3,42 4,42 6,36 3,67 6,00 8,08
Heating kW 4,27 5,03 6,50 4,92 6,40 9,23 5,12 8,55 11,72
Dp Cooling kPa 10,9 14,3 21,6 9,4 14,7 26,9 9,4 21,8 35,6
Dp Heating kPa 7,0 9,4 15,0 7,1 11,4 22,0 7,6 19,2 33,8
Sound power Lw dB(A) 33 40 48 34 40 53 34 48 58
Sound pressure Lp (*) dB(A) 24 31 39 25 31 44 25 39 49
Fan W 33 48 77 42 63 120 42 95 170
  А 0,15 0,23 0,63 0,18 0,28 0,53 0,18 0,42 0,74
Water content l 3,0 4,0 4,0
Dimensions mm 820×820×303

COOLING
Entering air temperature +27 °C d.b. + 19 °C w.b.
Water temperature +7 °C E.W.T. + 12 °C L.W.T.
HEATING
Entering air temperature +20 °C
Water temperature +65 °C E.W.T. +55 °C L.W.T.

 

Condensate pump absorption: 10 W
(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a
100 m3 room and a reverberation time of 0.5 sec.

 

 

4 pipe units

 

Specifications Units TL 0.4T TL 1.4T TL 2.4T TL 2.6T
Speed   1 2 3 1 2 3 1 2 3 1 2 3
Air flow m3/h 310 420 610 310 420 520 310 500 710 320 500 720
Cooling total emission kW 1,49 1,93 2,27 1,83 2,33 2,66 1,83 2,61 3,27 2,07 3,02 3,86
Cooling sensible emission kW 1,13 1,52 1,84 1,32 1,68 1,94 1,32 1,94 2,49 1,47 2,20 2,88
Dp Cooling kPa 6,0 10,0 13,5 4,6 6,9 8,8 4,6 8,8 13,4 4,0 7,0 10,5
Heating kW 1,72 2,23 2,66 2,13 2,66 3,04 2,13 3,04 3,86 1,73 2,71 2,91
Dp Heating kPa 5,2 8,3 11,4 4,6 6,8 8,7 4,6 8,7 13,3 2,6 4,6 6,7
Sound power Lw dB(A) 33 40 49 33 40 45 33 45 53 33 45 53
Sound pressure Lp (*) dB(A) 24 31 40 44 31 36 24 36 44 24 36 44
Fan W 25 32 57 25 32 44 25 44 68 25 44 68
  А 0,11 0,15 0,27 0,11 0,15 0,20 0,11 0,20 0,32 0,11 0,20 0,32
Cooling water content l 1,0 1,4 1,4 1,7
Heating water content l 0,6 0,7 0,7 0,5
Dimensions mm 575×575×275

 

 

Specifications Units TL 3.4T TL 3.6T TL 4.4T TL 5.4T
Speed   1 2 3 1 2 3 1 2 3 1 2 3
Air flow m3/h 430 610 880 430 610 880 630 820 1140 710 970 1500
Cooling total emission kW 2,33 2,96 3,72 2,69 3,47 4,44 4,11 4,98 6,26 4,48 5,60 7,59
Cooling sensible emission kW 1,72 2,23 2,88 1,94 2,56 3,37 2,93 3,60 4,61 3,21 4,09 5,71
Dp Cooling kPa 7,2 11,2 17,0 6,0 9,0 14,0 8,8 12,5 18,9 10,3 15,4 26,9
Heating kW 2,61 3,33 4,19 2,14 2,66 3,29 5,21 6,33 8,02 5,69 7,15 9,66
Dp Heating kPa 6,4 9,9 15,0 3,9 5,7 8,4 7,9 11,2 17,2 9,3 14,0 24,0
Sound power Lw dB(A) 41 49 59 41 49 59 33 40 48 34 40 53
Sound pressure Lp (*) dB(A) 32 40 50 32 40 50 24 31 39 25 31 44
Fan W 32 57 90 32 57 90 33 48 77 42 63 120
  А 0,15 0,27 0,45 0,15 0,27 0,45 0,15 0,23 0,36 0,18 0,28 0,53
Cooling water content l 1,4 1,7 3,0 3,0
Heating water content l 0,7 0,5 1,4 1,4
Dimensions mm 575×575×275 820×820×303

 

Specifications Units TL 5.6T TL 6.4T TL 6.6T
Speed   1 2 3 1 2 3 1 2 3
Air flow m3/h 710 970 1500 710 1280 1820 710 1225 1730
Cooling total emission kW 4,95 6,27 8,65 4,48 6,84 8,72 4,95 7,75 9,69
Cooling sensible emission kW 3,49 4,49 6,37 3,21 5,09 6,67 3,49 5,64 7,26
Dp Cooling kPa 9,0 14,0 25,0 10,3 22,1 34,7 9,0 20,0 32,0
Heating kW 4,59 5,63 7,50 5,69 8,80 11,16 4,59 6,78 9,48
Dp Heating kPa 4,9 7,0 11,8 9,3 20,3 31,2 4,9 9,9 15,0
Sound power Lw dB(A) 34 40 53 34 48 58 34 48 58
Sound pressure Lp (*) dB(A) 25 31 44 25 39 49 25 39 49
Fan W 42 63 120 42 95 170 42 95 170
  А 0,18 0,28 0,53 0,18 0,42 0,74 0,18 0,42 0,74
Cooling water content l 3,6 3,0 3,6
Heating water content l 1,0 1,4 1,1
Dimensions mm 820×820×303

COOLING
Entering air temperature +27 °C d.b. + 19 °C w.b.
Water temperature +7 °C E.W.T. + 12 °C L.W.T.
HEATING
Entering air temperature +20 °C
Water temperature +65 °C E.W.T. +55 °C L.W.T.

 

 

Condensate pump absorption: 10 W
(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a
100 m3 room and a reverberation time of 0.5 sec.

Dimensions
TL 0.2T-0.4T / TL 1.2T-1.4T / TL 2.2T-2.4T-2.6T / TL 3.2T-3.4T-3.6T (Version 600 x 600)
Dimensions

2-pipe system


Heating/cooling
3 - Inlet Ø1/2"
4 - Outlet Ø1/2"

 

4-pipe system

 

Heating

1 - Ø1/2" inlet

2 - Outlet Ø1/2"

 

Cooling

3 - Inlet Ø1/2"

4 - Outlet Ø1/2"

 

Model Fan coil Panel Packed unit Dimensions, mm
  Weights
packed unit, kg
Weights
unpacked unit,
kg
Weights
packed unit,
kg
Weights
unpacked unit,
kg
A B C D
TL 0.2T/1.2T 28 22            
TL 0.4T/1.4T     6 3 790 350 750 150
TL 2.2T/2.4T/2.6T 30 24            
TL 3.2T/3.4T/3.6T                

L 4.2T-4.4T / TL 5.2T-5.4T-5.6T / TL 6.2T-6.4T-6.6T (Version 800 x 800)